Storcli: Difference between revisions

From DWIKI
 
(6 intermediate revisions by the same user not shown)
Line 8: Line 8:


=HOWTO=
=HOWTO=
==Virtual Devices==
storcli /c0/v1 set name=myname
note: do not confuse VG with DG
==Add new/replacement disk==
==Add new/replacement disk==
Show all should tell you s(Slot), dg, array and row, then:
Show all should tell you s(Slot), dg, array and row, then:
Line 50: Line 54:
===BBU status values===
===BBU status values===
Check [https://github.com/prometheus-community/node-exporter-textfile-collector-scripts/issues/27 here] for more confusion
Check [https://github.com/prometheus-community/node-exporter-textfile-collector-scripts/issues/27 here] for more confusion
*0: OK  
*0: OK  
*8: charging or not full, unclear
*8: charging or not full, unclear
*16: cachevault?  
*16: cachevault?  
*32: manual learn requested
*32: manual learn requested
*40: learning?
*112: discharging for learning cycle?


{| class="wikitable"
|+ BBU status values
|-
! Dec !! Binary !! Hex !! Description
|-
| 8 || 1000  || 0x08 || charging?
|-
| 16 || 10000  || 0x10 || discharging?
|-
| 32 || 100000  || 0x20 || Learn Cycle Requested
|-
| 64 || 1000000 || 0x40 || Learn Cycle Active
|-
| 1024 ||  10000000000 ||  0x400 || Replace battery
|-
| 2024 || 100000000000 ||  0x800 || Total failure to communicate with BBU
|-
| 2152 || 100001101000 || 0x868 || ??
|}


==Get smart status of disk==
==Get smart status of disk==
  /dev/bus/0 -d sat+megaraid,14
  /dev/bus/0 -d sat+megaraid,14
Where '''14''' is disk ID, not Slot number
Where '''14''' is disk ID (DID), not Slot number


==Set disk to JBOD==
==Set disk to JBOD==
Line 133: Line 159:
There migh be a "cachevault"?
There migh be a "cachevault"?
  storcli /c0/cv show status
  storcli /c0/cv show status
[[Category:Raid]]

Latest revision as of 13:35, 26 April 2024

Links

HOWTO

Virtual Devices

storcli /c0/v1 set name=myname

note: do not confuse VG with DG

Add new/replacement disk

Show all should tell you s(Slot), dg, array and row, then:

storcli /c0/e32/s12 insert dg=0 array=0 row=0
storcli /c0/e32/s12 start rebuild


Locate a disk

storcli /c0/e8/s2 start locate


Show rebuild status

storcli /c0 /eall /sall show rebuild

Drive mappings

sg_map -x

Output: /dev/sgXX <host_number> <bus> <scsi_id> <lun> <scsi_type> <disk>

/dev/sg11  7 0 1 0  0  /dev/sdl

<scsi_id> is VD(DID?) in storcli output, this is not always same as DG :)

TODO find out where that '7' comes from

Alarm

Silence alarm

storcli /c0 set alarm=off


BBU

Show time

storcli /c0 show time

Get BBU status

storcli /cx/bbu show all

BBU start learn

storcli /cx/bbu start learn

BBU status values

Check here for more confusion

  • 0: OK
  • 8: charging or not full, unclear
  • 16: cachevault?
  • 32: manual learn requested
  • 40: learning?
  • 112: discharging for learning cycle?
BBU status values
Dec Binary Hex Description
8 1000 0x08 charging?
16 10000 0x10 discharging?
32 100000 0x20 Learn Cycle Requested
64 1000000 0x40 Learn Cycle Active
1024 10000000000 0x400 Replace battery
2024 100000000000 0x800 Total failure to communicate with BBU
2152 100001101000 0x868 ??

Get smart status of disk

/dev/bus/0 -d sat+megaraid,14

Where 14 is disk ID (DID), not Slot number

Set disk to JBOD

If disk still in an array, first delete that :) Looks like disks should be in state UGood

storcli /cx[/ex]/sx set jbod

If that fails try:

storcli /c0 set jbod=on

this might/should set all unused drives to jbod

Else look at:

storcli /c0/e9/s0 start erase simple

or if that fails

storcli /c0/e9/s0 start erase

this takes a while, check with

storcli /c0/e9/s0 show erase

FAQ

Failure 255 Operation not allowed.

Disk still in an array?

Output

UGood F

Disk contains foreign config, clear with

storcli /c0/fall del

Virtual Devices

NRWBD

NR=No Read Ahead WB = Write Back D = Direct IO

 

Cache settings

read ahead

usually on, pointless i reads are very random

write back

Faster, assumes you have BBU

FAQ

List controllers

storcli show all

VD settings with SSD

Set bootable

storcli /c0/e10/s0 set bootdrive= on|off

NO read ahead, write through

storcli /c0 /v2 set wrcache=wt

No read ahead

storcli /c0 /v2 set rdcache=nora

Changing cache settings

storcli /c0 /v1 set wrcache=wt|wb|awb
storcli /c0 /v1 set rdcache=ra|nora



ErrMsg: use /cx/cv

There migh be a "cachevault"?

storcli /c0/cv show status