Storcli

From DWIKI
Revision as of 12:47, 21 March 2023 by Tony (talk | contribs)

Links

HOWTO

Add new/replacement disk

Show all should tell you s(Slot), dg, array and row, then:

storcli /c0/e32/s12 insert dg=0 array=0 row=0
storcli /c0/e32/s12 start rebuild


Locate a disk

storcli /c0/e8/s2 start locate


Show rebuild status

storcli /c0 /eall /sall show rebuild


Alarm

Silence alarm

storcli /c0 set alarm=off


BBU

Show time

storcli /c0 show time

Get BBU status

storcli /cx/bbu show all

BBU start learn

storcli /cx/bbu start learn

BBU status values

Check here for more confusion

  • 0: OK
  • 8: charging or not full, unclear
  • 16: cachevault?
  • 32: manual learn requested

Output

UGood F

Disk contains foreign config, clear with

storcli /c0/fall del

Virtual Devices

NRWBD

NR=No Read Ahead WB = Write Back D = Direct IO

 

Cache settings

read ahead

usually on, pointless is reads are very random

 

write back

FAQ

List controllers

storcli show all

VD settings with SSD

NO read ahead, write through

storcli /c0 /v2 set wrcache=wt

No read ahead

storcli /c0 /v2 set rdcache=nora

Changing cache settings

storcli /c0 /v1 set wrcache=wt|wb|awb
storcli /c0 /v1 set rdcache=ra|nora



ErrMsg: use /cx/cv

There migh be a "cachevault"?

storcli /c0/cv show status