Conbee

From DWIKI
Revision as of 17:33, 5 May 2021 by Tony (talk | contribs)

Links

Howto

Connecting Conbee 2

Steps:

https://phoscon.de/en/conbee/install

https://github.com/Smanar/Domoticz-deCONZ


Configuration

/lib/systemd/system/deconz* /usr/share/deCONZ/zcl/general.xml

Change ports

  1. /etc/systemd/system/deconz.service.d/override.conf
[Service]
ExecStart=
ExecStart=/usr/bin/deCONZ -platform minimal --http-port=8080 --ws-port=8081 --auto-connect=1 --dbg-error=1



FAQ

ExecStart=/usr/bin/deCONZ -platform minimal --http-port=80 -debug-error=1 (code=exited, status=218/CAPABILITIES)

A systemd problem, fix/override of deconz.service works for me

 

Sensor not reachable

After a reboot phoscon sometimes reports sensor not reachable. First thing to try is press button on the sensor.

 

Connecting Innr SP120

In Phoscon interface that's under Devices->Lights "add new light", not a switch!

 


Xiaomi smart plug

found as LUMI, lumi.plug.mmeu01, ZNCZ04LM

https://github.com/dresden-elektronik/deconz-rest-plugin/issues/2583

Leds:

  • red blinking fast: overheat
  • red blink slowly: not connected
  • blue on: working 
  • blue blinking: connecting

GUI says "not connected"

Most likely because service 'deconz' is already running. Try

systemctl stop deconz.service