Storcli
Links
HOWTO
Virtual Devices
storcli /c0/v1 set name=myname
note: do not confuse VG with DG
Add new/replacement disk
Show all should tell you s(Slot), dg, array and row, then:
storcli /c0/e32/s12 insert dg=0 array=0 row=0 storcli /c0/e32/s12 start rebuild
Locate a disk
storcli /c0/e8/s2 start locate
Show rebuild status
storcli /c0 /eall /sall show rebuild
Drive mappings
sg_map -x
Output: /dev/sgXX <host_number> <bus> <scsi_id> <lun> <scsi_type> <disk>
/dev/sg11 7 0 1 0 0 /dev/sdl
<scsi_id> is VD(DID?) in storcli output, this is not always same as DG :)
TODO find out where that '7' comes from
Alarm
Silence alarm
storcli /c0 set alarm=off
BBU
Show time
storcli /c0 show time
Get BBU status
storcli /cx/bbu show all
BBU start learn
storcli /cx/bbu start learn
BBU status values
Check here for more confusion
- 0: OK
- 8: charging or not full, unclear
- 16: cachevault?
- 32: manual learn requested
- 40: learning?
- 112: discharging for learning cycle?
Dec | Binary | Hex | Description |
---|---|---|---|
8 | 1000 | 0x08 | charging? |
16 | 10000 | 0x10 | discharging? |
32 | 100000 | 0x20 | Learn Cycle Requested |
64 | 1000000 | 0x40 | Learn Cycle Active |
1024 | 10000000000 | 0x400 | Replace battery |
2024 | 100000000000 | 0x800 | Total failure to communicate with BBU |
2152 | 100001101000 | 0x868 | ?? |
Get smart status of disk
/dev/bus/0 -d sat+megaraid,14
Where 14 is disk ID (DID), not Slot number
Set disk to JBOD
If disk still in an array, first delete that :) Looks like disks should be in state UGood
storcli /cx[/ex]/sx set jbod
If that fails try:
storcli /c0 set jbod=on
this might/should set all unused drives to jbod
Else look at:
storcli /c0/e9/s0 start erase simple
or if that fails
storcli /c0/e9/s0 start erase
this takes a while, check with
storcli /c0/e9/s0 show erase
FAQ
Failure 255 Operation not allowed.
Disk still in an array?
Output
UGood F
Disk contains foreign config, clear with
storcli /c0/fall del
Virtual Devices
NRWBD
NR=No Read Ahead WB = Write Back D = Direct IO
Cache settings
read ahead
usually on, pointless i reads are very random
write back
Faster, assumes you have BBU
FAQ
List controllers
storcli show all
VD settings with SSD
Set bootable
storcli /c0/e10/s0 set bootdrive= on|off
NO read ahead, write through
storcli /c0 /v2 set wrcache=wt
No read ahead
storcli /c0 /v2 set rdcache=nora
Changing cache settings
storcli /c0 /v1 set wrcache=wt|wb|awb storcli /c0 /v1 set rdcache=ra|nora
ErrMsg: use /cx/cv
There migh be a "cachevault"?
storcli /c0/cv show status
Error messagess
Description = physical disk does not have appropriate attributes
Does it happen to show DG as "F"? try
storcli /c0/fall show
and
storcli /c0/fall delete
Also set to UGood