Smart: Difference between revisions

From DWIKI
Line 125: Line 125:
== Device: /dev/bus/0 [megaraid_disk_09] [SAT], failed to read SMART Attribute Data ==
== Device: /dev/bus/0 [megaraid_disk_09] [SAT], failed to read SMART Attribute Data ==


Controller probably doesn't allow smart,
Controller probably doesn't allow smart, it also seems to happen when drive is hot spare on megamaid controller.
 


==FAILURE PREDICTION THRESHOLD EXCEEDED [asc=5d, ascq=0]==
==FAILURE PREDICTION THRESHOLD EXCEEDED [asc=5d, ascq=0]==

Revision as of 08:47, 29 June 2023

Disk monitoring

Links

Tools

  • smartctl
  • gsmartcontrol

 

Useful commands

enable smart

smartctl -i /dev/sda

check smart status

smartctl -a /dev/sda

check smart status of disk in raid array

Something like

smartctl -a /dev/bus/0 -d sat+megaraid,11

check error log

smartctl -l error /dev/sdb
      

Device: /dev/bus/0 [megaraid_disk_09] [SAT]

Try

smartctl --scan

 

 

Some codes and messages


LBA_of_first_error

 

Device is: Not in smartctl database [for details use: -P showall]

Try

/usr/sbin/update-smart-drivedb

otherwise check out https://www.smartmontools.org/wiki/FAQ#MyATASATAdriveisnotinthesmartctlsmartddatabase

Uncorrectable Sector Count

Check https://medium.com/@satyeshukumar/how-to-fix-uncorrectable-sector-count-warning-5a38c56d3faf

198 Offline Uncorrectable

bad sign, on ssd mostly/only when number gets high

 


SSD specific

231 SSD_Life_Left

Percentage of life left

233 Media Wearout Indicator

241 Lifetime_Writes_GiB

Amount of data written so far

smartd: Failed SMART usage Attribute

Might be yelling about a disk that's already been replaced, try restarting smartd

Error: UNC at LBA = 0x00113cd8 = 1129688

Uncorrectable LBA error, throw away

FAQ

Wear level

Wear level on nvme

There's percentage used: High = bad

and available spare

Low = bad


List disks

smartctl --scan

A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.

meh

 

Device: /dev/bus/0 [megaraid_disk_09] [SAT], failed to read SMART Attribute Data

Controller probably doesn't allow smart, it also seems to happen when drive is hot spare on megamaid controller.

FAILURE PREDICTION THRESHOLD EXCEEDED [asc=5d, ascq=0]

time to replace disk?


/dev/sdc: Unknown USB bridge

Smart over USB usually doesn't do much, try

smartctl -a -d scsi /dev/sdc

to get some information


Unavailable - device lacks SMART capability.

??