Apcupsd: Difference between revisions
From DWIKI
Created page with "=Links= *http://www.apcupsd.org/ =FAQ= ==COMMLOST== If connecting via USB: in apcupsd.conf: DEVICE" |
Tag: wikieditor |
||
| (12 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
=Links= | =Links= | ||
*http://www.apcupsd.org/ | *[http://www.apcupsd.org/ apcupsd homepage] | ||
==Documentation== | |||
*[https://help.ubuntu.com/community/apcupsd apcupsd at Ubuntu site] | |||
*https://wiki.debian.org/apcupsd | |||
*https://wiki.alpinelinux.org/wiki/Apcupsd | |||
=Scripts= | |||
==apcaccess== | |||
[https://man.archlinux.org/man/apcaccess.8.en man(8) apcaccess[ | |||
===Values=== | |||
====MBATTCHG==== | |||
When battery charge drops below this value, shutdown is initiated. | |||
====STATUS==== | |||
====TIMELEFT==== | |||
The UPS battery run time remaining before battery | |||
exhaustion. | |||
====LOADPCT==== | |||
The current UPS load expressed in percent | |||
of rated capacity. | |||
=HOWTO= | |||
==Test configuration== | |||
apctest | |||
==Shutdown when communication with UPS is lost== | |||
Look for 'commfailure' and apccontrol script, but looks like a bad plan. | |||
=Apcupsd using SNMP= | |||
On the UPS enable SNMP and have a community (for example '''public''') with read access. | |||
In /etc/apcupsd/apcupsd.conf: | |||
UPSCABLE ether | |||
UPSTYPE snmp | |||
DEVICE 192.168.188.12:161:APC:public | |||
After starting apcupsd check it with | |||
apcaccess | |||
(this can be run as non-root) | |||
This only works with | |||
NETSERVER on | |||
==FAQ== | |||
===acpaccess does not provide info like TIMELEFT=== | |||
apt install snmp | |||
=FAQ= | =FAQ= | ||
==COMMLOST== | ==COMMLOST== | ||
TODO finish this | |||
If connecting via USB: | If connecting via USB: | ||
in apcupsd.conf: | in apcupsd.conf: | ||
DEVICE | DEVICE | ||
==snmplite Missing hostname== | |||
You probably forgot the DEVICE line | |||
Latest revision as of 14:15, 23 April 2026
Links
Documentation
Scripts
apcaccess
[https://man.archlinux.org/man/apcaccess.8.en man(8) apcaccess[
Values
MBATTCHG
When battery charge drops below this value, shutdown is initiated.
STATUS
TIMELEFT
The UPS battery run time remaining before battery exhaustion.
LOADPCT
The current UPS load expressed in percent of rated capacity.
HOWTO
Test configuration
apctest
Shutdown when communication with UPS is lost
Look for 'commfailure' and apccontrol script, but looks like a bad plan.
Apcupsd using SNMP
On the UPS enable SNMP and have a community (for example public) with read access.
In /etc/apcupsd/apcupsd.conf:
UPSCABLE ether UPSTYPE snmp DEVICE 192.168.188.12:161:APC:public
After starting apcupsd check it with
apcaccess
(this can be run as non-root) This only works with
NETSERVER on
FAQ
acpaccess does not provide info like TIMELEFT
apt install snmp
FAQ
COMMLOST
TODO finish this If connecting via USB: in apcupsd.conf:
DEVICE
snmplite Missing hostname
You probably forgot the DEVICE line