Megacli: Difference between revisions

From DWIKI
mNo edit summary
mNo edit summary
Line 2: Line 2:
= Links =
= Links =


*[http://erikimh.com/megacli-cheatsheet/ MegaCli Cheat sheet]
*[http://erikimh.com/megacli-cheatsheet/ MegaCli Cheat sheet]  
*[https://www.ibm.com/support/pages/megaraid-storage-manager-reports-unexpected-sense-codes-servers Unexpected Sense codes]  
*[https://www.t10.org/lists/1spc-lst.htm SCSI codes]


= Megaraid command line tool =
= Megaraid command line tool =
Line 74: Line 74:
  MegaCli -PDMarkMissing -PhysDrv \[E:S\] -aN
  MegaCli -PDMarkMissing -PhysDrv \[E:S\] -aN
  MegaCli -PDPrpRmv -PhysDrv [E:S] -aN
  MegaCli -PDPrpRmv -PhysDrv [E:S] -aN
== Unexpected sense code ==
*[https://www.t10.org/lists/1spc-lst.htm check here]

Revision as of 09:32, 7 December 2020

Links

Megaraid command line tool

Drive mappings

Shown as Disk0 (Slot number 0) by megacli

Enclosure Device ID: 10 Slot Number: 0 Enclosure position: 0 Device Id: 13 Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Inquiry Data: X9O1S0V1S5HHTOSHIBA HDWD240 KQ000A

In smart it's

/dev/bus/0 -d sat+megaraid,13

Commands

Show all info

MegaCli -AdpAllInfo -a0

Show all drives

MegaCli -PDList -aALL

 

Virtual/physical drives

megaCli -LdPdInfo -a0

 

Show BBU status

megacli -AdpBbuCmd -a0 -nolog

Show array status

MegaCli -LdInfo L1 -a0 -nolog

 

Locate one drive

Where '6' is the Slot Number from pdlist/pdfino and '252'  the Enclosure device id.

MegaCli64 -PdLocate -start -physdrv \[252:6\] -a0

 

FAQ

Primary-5, Secondary-0, RAID Level Qualifier-3

https://globalroot.wordpress.com/2013/06/18/megacli-raid-levels/

Replace a drive

MegaCli -PDOffline -PhysDrv \[E:S\] -aN
MegaCli -PDMarkMissing -PhysDrv \[E:S\] -aN
MegaCli -PDPrpRmv -PhysDrv [E:S] -aN


Unexpected sense code