Megacli: Difference between revisions
From DWIKI
mNo edit summary |
mNo edit summary |
||
Line 1: | Line 1: | ||
= Megaraid command line tool = | |||
*[http://tools.rapidsoft.de/perc/perc-cheat-sheet.pdf http://tools.rapidsoft.de/perc/perc-cheat-sheet.pdf] | |||
*[http://erikimh.com/megacli-cheatsheet/ http://erikimh.com/megacli-cheatsheet/] | |||
*[http://tools.rapidsoft.de/perc/ http://tools.rapidsoft.de/perc/] | |||
*[https://exxa.tech/linux/lsi-megaraid-command-line-utility https://exxa.tech/linux/lsi-megaraid-command-line-utility] | |||
*[http://www.lsi.com/DistributionSystem/AssetDocument/files/docs/techdocs/storage_stand_prod/sas/embedded_mr_sw_ug.pdf http://www.lsi.com/DistributionSystem/AssetDocument/files/docs/techdocs/storage_stand_prod/sas/embedded_mr_sw_ug.pdf] | |||
*[https://www.advancedclustering.com/act_kb/replacing-a-disk-with-megacli/ Replacing a disk with megacli] | |||
*[https://raid.wiki.kernel.org/index.php/Hardware_Raid_Setup_using_MegaCli Megacli on Linux] | |||
= Drive mappings = | = Drive mappings = |
Revision as of 11:13, 19 November 2020
Megaraid command line tool
- http://tools.rapidsoft.de/perc/perc-cheat-sheet.pdf
- http://erikimh.com/megacli-cheatsheet/
- http://tools.rapidsoft.de/perc/
- https://exxa.tech/linux/lsi-megaraid-command-line-utility
- http://www.lsi.com/DistributionSystem/AssetDocument/files/docs/techdocs/storage_stand_prod/sas/embedded_mr_sw_ug.pdf
- Replacing a disk with megacli
- Megacli on Linux
Drive mappings
Shown as Disk0 (Slot number 0) by megacli
Enclosure Device ID: 10 Slot Number: 0 Enclosure position: 0 Device Id: 13 Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Inquiry Data: X9O1S0V1S5HHTOSHIBA HDWD240 KQ000A
In smart it's
/dev/bus/0 -d sat+megaraid,13
Commands
Show all info
MegaCli -AdpAllInfo -a0
Show all drives
MegaCli -PDList -aALL
Virtual/physical drives
megaCli -LdPdInfo -a0
Show BBU status
megacli -AdpBbuCmd -a0 -nolog
Show array status
MegaCli -LdInfo L1 -a0 -nolog
Locate one drive
Where '6' is the Slot Number from pdlist/pdfino and '252' the Enclosure device id.
MegaCli64 -PdLocate -start -physdrv \[252:6\] -a0
FAQ
Primary-5, Secondary-0, RAID Level Qualifier-3
https://globalroot.wordpress.com/2013/06/18/megacli-raid-levels/